UK Next Day Delivery Available
5 Year Warranty
30 Day Returns
PRODUCT CODE 6001

SANIFLO UP 6001

Complete product information and installation guide for the Saniflo UP 6001 WC macerator, including installation diagrams, pipe sizes, pumping distances, technical specifications, electrical requirements, maintenance and troubleshooting.

400W MOTOR
1 WC INLET
4m MAX HEIGHT
46dB NOISE LEVEL
35°C MAX TEMP
6001 PRODUCT CODE
SANIFLO • PRODUCT CODE 6001

Saniflo UP Macerator Pump

Compact domestic macerator designed for connection to a single WC. View the complete product listing and order the Saniflo UP 6001 directly from Macerator-Pumps.com.

✓ WC Only ✓ 400W Motor ✓ 22 / 28 / 32mm Discharge ✓ Up to 4m Vertical Lift
PRODUCT INFORMATION

About the Saniflo UP 6001

The Saniflo UP is a domestic macerator designed for a WC only. Its compact design allows a toilet to be installed in locations where conventional gravity drainage may not be practical.

🚽

Designed for One WC

The Saniflo UP has one 100 mm external inlet and is specifically designed as a WC-only macerator.

🔧

Top Maintenance Access

Maintenance access is provided from the top of the unit to make inspection and servicing easier.

⚙️

Direct Basket Access

In the event of a blockage caused by improper use, the basket can be accessed without dismantling the complete unit or emptying the tank.

↔️

Replacement Friendly

Identical pipe centres are designed to make replacement of an older compatible model easier.

Saniflo UP 6001 installation overview
Saniflo UP 6001 installation and discharge guidance.
APPLICATION

What Can the Saniflo UP Connect To?

The Saniflo UP 6001 is designed specifically for a single horizontally connected WC.

🚽 WC / Toilet

This model has one 100 mm external inlet. It is not the multi-inlet Saniflo model for connecting additional bathroom appliances such as a basin or shower.

PIPE CONNECTIONS

Saniflo UP Connection Sizes

100mm WC Inlet Single external WC inlet.
22mm Discharge Option External pumped discharge.
28 / 32mm Discharge Options Alternative external discharge sizes.
Saniflo UP 6001 installation pipework
Saniflo UP pipework arrangement and installation guidance.
INSTALLATION GUIDE

Installing the Saniflo UP 6001

The diagrams supplied with the unit show the correct WC positioning, discharge arrangement, fixing method and maintenance access.

1

Plan the Position

Position the macerator directly behind the horizontally connected WC and plan the discharge route before fixing.

2

Keep the Unit Accessible

Leave sufficient access around the unit for future checks, maintenance and servicing.

3

Connect the WC

Connect the horizontal WC outlet securely to the 100 mm external inlet on the macerator.

4

Fit the Discharge

Configure the pumped discharge using the appropriate 22, 28 or 32 mm external connection.

5

Secure the Unit

Use the supplied fixing components and follow the fixing arrangement illustrated in the installation guide.

6

Connect the Electrical Supply

Electrical installation must be completed by a qualified electrical engineer in accordance with the supplied instructions.

7

Commission the Unit

Flush the WC and check that the unit activates, pumps correctly and all plumbing connections remain watertight.

8

Check Discharge Pipework

Inspect the complete discharge route and make sure it follows the installation arrangement shown in the manufacturer's guide.

Saniflo UP 6001 discharge installation
Discharge fittings and WC connection instructions.
WC CONNECTION

Positioning the Saniflo UP Behind the Toilet

The installation diagram specifies a maximum distance of 20 cm between the WC outlet and the macerator.

Maximum WC Connection Distance: 20 cm

Keep the unit close to the WC outlet and follow the orientation shown in the supplied installation diagrams.

Saniflo UP 6001 fixing instructions
Saniflo UP fixing and WC connection instructions.
MAINTENANCE ACCESS

Top Access for Maintenance

The Saniflo UP incorporates access from the top of the unit. The supplied installation guide illustrates how the access cover is removed to reach the internal basket.

⚠️
Disconnect the electrical supply first.

The operating manual states that electrical power must be disconnected before working on the unit. Do not place your hand into the cutter area.

Saniflo UP maintenance access
Saniflo UP top maintenance access and cutter-area guidance.
DISCHARGE PERFORMANCE

Saniflo UP Pumping Distances

The maximum available horizontal discharge distance reduces as the vertical lift increases.

1 metre vertical lift
Maximum 90 metres horizontal
2 metres vertical lift
Maximum 80 metres horizontal
3 metres vertical lift
Maximum 60 metres horizontal
4 metres vertical lift
Maximum 40 metres horizontal
ℹ️
Vertical and horizontal maximums are not simultaneous.

At the recommended maximum lift of 4 metres, the supplied installation diagram shows a maximum horizontal discharge distance of 40 metres.

Saniflo UP 6001 dimensions and pumping performance
Saniflo UP technical dimensions, pumping curve and discharge performance.
TECHNICAL INFORMATION

Saniflo UP 6001 Specifications

Product
Saniflo UP
Product Code
6001
Application
Domestic only
Suitable For
WC / Toilet only
Number of Inlets
1
External Inlet Diameter
100 mm
External Discharge Diameter
22 / 28 / 32 mm
Motor Power
400 W
Voltage / Frequency
220–240 V / 50–60 Hz
Maximum Incoming Temperature
35°C
Recommended Maximum Height
4 metres
Noise Level
46 dB(A)
IP Rating
IP44
Electrical Class
Class I
Cutter
Single blade cutter
Unit Weight
5.4 kg
Gross Weight
6 kg
Barcode
3308815074191
Standard
EN 12050-3
DIMENSIONS

Saniflo UP Dimensions

The supplied dimensional drawing shows the compact footprint of the Saniflo UP. Always allow additional space for the WC connection, discharge pipework and maintenance access.

339mm Main Body Width As shown on the product dimensional drawing.
222mm Body Depth As shown on the dimensional drawing.
264mm Body Height Refer to the diagram for individual connection heights.
ELECTRICAL CONNECTION

UK Electrical Installation

Electrical installation must be completed in accordance with the supplied Saniflo operating instructions.

⚡
Electrical installation must be carried out by a qualified electrical engineer.

The GB operating manual specifies a fully earthed Class I 220/240 V single-phase AC 50 Hz supply. It states that the unit should not be connected to a conventional plug and socket and should instead be wired into a fused, unswitched fixed-wiring connector fitted with a 5 amp fuse. Disconnect electrical power before working on the unit.

IN THE BOX

Saniflo UP Pack Contents

✓ Saniflo UP macerator
✓ Non-return valve
✓ Connection components
✓ Activated carbon filter to neutralise odours
OPTIONAL EXTRAS

Compatible Saniflo Accessories

🔔

Sanialarm

Sanialarm accessory – Saniflo product code 1095.

🧴

Saniflo Descaler

Saniflo Descaler – product code 1085.

MAINTENANCE

Looking After Your Saniflo UP

🧴

Regular Descaling

Use an appropriate descaling product in accordance with the operating instructions to help control scale inside the macerator.

🔍

Keep Access Clear

Do not permanently box the unit in without providing suitable access for inspection, maintenance and servicing.

⚡

Disconnect Before Work

Always disconnect the electrical power before carrying out work on or opening the unit.

⚙️

Basket Access

Top access allows the basket to be reached if a blockage occurs due to improper use without dismantling the complete unit.

TROUBLESHOOTING

Common Saniflo UP Problems

The motor does not activate
Check that electrical power is available to the unit. Electrical, motor or control faults should be investigated by an appropriately qualified person.
The motor rattles, crunches or hums
A foreign object may be obstructing the macerator. Disconnect the electrical supply before any intervention.
The Saniflo activates intermittently
Check the WC and water supply for unwanted water entering the unit. A non-return valve issue may also require inspection.
The motor runs for too long
Check the discharge installation, including its vertical height, horizontal length and number of bends, against the installation requirements.
The unit stops during operation
If the unit has been operating for an extended period, allow it to cool. If the problem continues, the unit should be inspected by an appropriate service engineer.

Buy the Saniflo UP 6001

View the complete product listing and order the Saniflo UP 6001 from Macerator-Pumps.com.

£445
View Product & Buy Now →
Scroll to Top
By Macerator Pumps

Keep Updated With New Products & Offers

Sign up to receive our latest product updates, special offers and news.

By subscribing, you agree to our Privacy Policy .